There are 9 questions to be attended in 20 minutes. The questions are on Measurement and Instrumentation. The study material is provided along with the remarks for each answer after you complete the examination to help building knowledge on the subject. It may be better to study before attempting the mock drill so that by the time you reach 9th of the test, you score is around 80-90%. There are 9 question banks of 9 question each and you should attempt each of these question bank to test your preparedness for the final day of the RRB examination for SSE and JE to be held in Dec.
Time limit: 0
Quiz-summary
0 of 9 questions completed
Questions:
1
2
3
4
5
6
7
8
9
Information
There are 9 questions to be attended in 20 minutes. The questions are on Measurement and Instrumentation. Read the study material before making an attempt so that you build your confidence in the subject. This is the ninth of the series of 9 questions paper that will appear before the RRB examination for SSE and JE to be held in Dec.
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 9 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score
Your score
Categories
Not categorized0%
The Answer Key:
Sl No.
Question
Answer
Remark
1
A spring balance deflection at 0, 1, 2, 3 kg is found be 0,20,40 and 60 mm at 20 degree centigrade but changes to 5, 27, 49 and 71 at 30 degree centigrade undergoing a zero and sensitivity drift. Calculate the Zero and sensitivity drift of the balance.
0.5 and 0.2
Zero drift is zero error and sensitivity drift measures the effect of temperature on the overall readings. Zero reading changes by 5 mm and persistent for all readings and therefore zero drift is 5/10=0.5 mm/°C. Other readings are affected due to zero as well as sensitivity and by subtracting zero drift from all the readings we get a sensitivity drift of 2 mm and therefore sensitivity drift is 2/10 or 0.2 mm/°C.
2
Unit of luminous intensity is
Candela
Luminous is a fundamental unit defines the lumen output per unit sterdian and its unit is candela.
3
The device used for measurement of time in present period is
Quartz Crystal
Quartz is the only crystal which exhibits the property of converting electrical signal to resonate at a defined frequency
4
Pressure at higher altitude reduces due to
reduced height of air column above
The height of the column above reduces as compared to plain thus the weight of the air and thus weight per unit area.
5
Measurement of dissipation factor is employed to find the
condition of Cables
Dissipation factor is also called measurement of Tanδ. When there is no loss through resistance, the current through the capacitance is in 90 degree phase but due to some loss, it is slightly out of phase. Measurement of this angle helps in indentifying the health of cables.
6
What measurement technique is followed for the measurement of very low value of vacuum of the order of 10⁻⁶
Pirani gauge
7
The working principle of Pirani Vacuum Gauge is
Principle of Thermal Conductivity
2nd is called Mcleod, 3rd is capacitive change and 4th is ionisation method.
8
Shaft encoders are used
to measure the angular position of shaft
It is a electro-mechanical device that converts the angular position or motion of a shaft into analogue or digital signal for many application in instrumentation and machinery.
9
Reed meters are used for the measurement of
Supply Frequency
Reed frequency meters works on the principle of fitting many reeds of frequency difference of 0.5 Hz and checking the reed which vibrates most to find out the frequency.
1
2
3
4
5
6
7
8
9
Answered
Review
Question 1 of 9
1. Question
A spring balance deflection at 0, 1, 2, 3 kg is found be 0,20,40 and 60 mm at 20 degree centigrade but changes to 5, 27, 49 and 71 at 30 degree centigrade undergoing a zero and sensitivity drift. Calculate the Zero and sensitivity drift of the balance.
Question 2 of 9
2. Question
Unit of luminous intensity is
Question 3 of 9
3. Question
The device used for measurement of time in present period is
Question 4 of 9
4. Question
Pressure at higher altitude reduces due to
Question 5 of 9
5. Question
Measurement of dissipation factor is employed to find the
Question 6 of 9
6. Question
What measurement technique is followed for the measurement of very low value of vacuum of the order of 10⁻⁶
The study content I have given along with the correct answer of the question. After you finish the quiz, press finish quiz, you will be taken to the page where each answer is there along with a remark to brief you on the content.
pls can u mail instrumentation ans measurement study metrial
The study content I have given along with the correct answer of the question. After you finish the quiz, press finish quiz, you will be taken to the page where each answer is there along with a remark to brief you on the content.
Yes, I also Need it.
quiz
Very nice stuff, it’s helpful alot